SIEMENS 6ES72221BF320XB0 SIMATIC S7-1200 Digital Ouput SM 1222 Module PLC

SIEMENS 6ES72221BF320XB0SIMATIC S7-1200, Digital output SM 1222, 8 DO, 24 V DC, transistor 0.5 A

Products Details

 
Article number 6ES7222-1BF32-0XB0 6ES7222-1BH32-0XB0 6ES7222-1BH32-1XB0 6ES7222-1HF32-0XB0 6ES7222-1HH32-0XB0 6ES7222-1XF32-0XB0
  Digital Output SM1222, 8 DO, 24V DC Digital Output SM1222, 16 DO, 24V DC Digital Output SM1222, 16DO, 24V DC sink Digital Output SM 1222, 8 DO, Relay Digital Output SM1222, 16 DO, Relay Digital Output SM 1222, 8 DO, Changeover
General information            
Product type designation SM 1222, DQ 8x24 V DC/0.5 A SM 1222, DQ 16x24 V DC/0.5 A SM 1222, DO 16x 24 V DC/0.5 A Sink SM 1222, DQ 8x relay/2 A SM 1222, DQ 16x relay/2 A SM 1222, DQ 8x relay/2 A
Supply voltage            
permissible range, lower limit (DC) 20.4 V 20.4 V 20.4 V 20.4 V 20.4 V 20.4 V
permissible range, upper limit (DC) 28.8 V 28.8 V 28.8 V 28.8 V 28.8 V 28.8 V
Input current            
from backplane bus 5 V DC, max. 120 mA 140 mA 140 mA 120 mA 135 mA 140 mA
Digital outputs            
● from load voltage L+, max.       11 mA/relay coil 11 mA/relay coil 16.7 mA/relay coil
Power loss            
Power loss, typ. 1.5 W 2.5 W 2.5 W 4.5 W 8.5 W 5 W
Digital outputs            
Number of digital outputs 8 16 16 8 16 8
● in groups of 1 1 1 2 1 1
Current-sinking     Yes      
Short-circuit protection No; to be provided externally No; to be provided externally No; to be provided externally No; to be provided externally No; to be provided externally No; to be provided externally
Limitation of inductive shutdown voltage to typ. (L+) -48 V typ. (L+) -48 V Typ 45 V      
Switching capacity of the outputs            
● with resistive load, max. 0.5 A 0.5 A 0.5 A 2 A 2 A 2 A
● on lamp load, max. 5 W 5 W 5 W 30 W with DC, 200 W with AC 30 W with DC, 200 W with AC 30 W with DC, 200 W with AC
Output voltage            
● Rated value (DC) 24 V 24 V 24 V 5 V DC to 30 V DC 5 V DC to 30 V DC 5 V DC to 30 V DC
● Rated value (AC)       5 V AC to 250 V AC 5 V AC to 250 V AC 5 V AC to 250 V AC
● for signal "0", max. 0.1 V; with 10 kOhm load 0.1 V; with 10 kOhm load L+ minus 0.75 V DC with 10k Load      
● for signal "1", min. 20 V DC 20 V DC 0,5 V      
Output current            
● for signal "1" rated value 0.5 A 0.5 A 0.5 A 2 A 2 A 2 A
● for signal "0" residual current, max. 10 µA 10 µA 75 µA      
Output delay with resistive load            
● "0" to "1", max. 50 µs 50 µs 20 µs 10 ms 10 ms 10 ms
● "1" to "0", max. 200 µs 200 µs 350 µs 10 ms 10 ms 10 ms
Total current of the outputs (per group)            
horizontal installation            
— up to 50 °C, max. 4 A; Current per mass 8 A; Current per mass 8 A; Current per mass 10 A; Current per mass 10 A; Current per mass 2 A; Current per mass
Relay outputs            
● Number of relay outputs       8 16 8
● Rated supply voltage of relay coil L+ (DC)       24 V 24 V 24 V
● Number of operating cycles, max.       mechanically 10 million, at rated load voltage 100 000 mechanically 10 million, at rated load voltage 100 000 mechanically 10 million, at rated load voltage 100 000
Switching capacity of contacts            
— with inductive load, max. 0.5 A 0.5 A 0.5 A 2 A 2 A 2 A
— on lamp load, max. 5 W 5 W 5 W 30 W with DC, 200 W with AC 30 W with DC, 200 W with AC 30 W with DC, 200 W with AC
— with resistive load, max. 0.5 A 0.5 A 0.5 A 2 A 2 A 2 A
Cable length            
● shielded, max. 500 m 500 m 500 m 500 m 500 m 500 m
● unshielded, max. 150 m 150 m 150 m 150 m 150 m 150 m
Interrupts/diagnostics/status information            
Alarms            
● Diagnostic alarm Yes Yes Yes Yes Yes Yes
Diagnostics indication LED            
● for status of the outputs Yes Yes Yes Yes Yes Yes
Potential separation            
Potential separation digital outputs            
● between the channels       Relays Relays Relays
● between the channels, in groups of 1 1 1 2 4 1
● between the channels and backplane bus 500 V AC 500 V AC 500 V AC 1 500 V AC for 1 minute 1 500 V AC for 1 minute 1 500 V AC for 1 minute
Permissible potential difference            
between different circuits       750 V AC for 1 minute 750 V AC for 1 minute 750 V AC for 1 minute