Description | Power supply GREYHOUND Switch only |
Operating Voltage | 60 to 250 V DC and 110 to 240 V AC |
Power consumption | 2.5 W |
Power output in BTU (IT)/h | 9 |
MTBF (MIL-HDBK 217F: Gb 25 ºC) | 757 498 h |
Operating temperature | 0-+60 °C |
Storage/transport temperature | -40-+70 °C |
Relative humidity (non-condensing) | 5-95 % |
Weight | 710 g |
Protection class | IP30 |
IEC 60068-2-6 vibration | 1 mm, 2 Hz-13.2 Hz, 90 min.; 0.7 g, 13.2 Hz-100 Hz, 90 min.; 3.5 mm, 3 Hz-9 Hz, 10 cycles, 1 octave/min.; 1 g, 9 Hz-150 Hz, 10 cycles, 1 octave/min |
IEC 60068-2-27 shock | 15 g, 11 ms duration, 18 shocks |
EN 61000-4-2 electrostatic discharge (ESD) | 8 kV contact discharge, 15 kV air discharge |
EN 61000-4-3 electromagnetic field | 35 V/m (80-2700 MHz); 1 kHz, 80% AM |
EN 61000-4-4 fast transients (burst) | 4 kV power line, 4 kV data line |
EN 61000-4-5 surge voltage | power line: 2 kV (line/earth), 1 kV (line/line); data line: 1 kV; IEEE1613: power line 5kV (line/earth) |
EN 61000-4-6 Conducted Immunity | 3 V (10 kHz-150 kHz), 10 V (150 kHz-80 MHz) |
EN 61000-4-16 mains frequency voltage | 30 V, 50 Hz continous; 300 V, 50 Hz 1 s |
EN 55032 | EN 55032 Class A |
Basis Standard | CE, FCC, EN61131 |
Safety of industrial control equipment | EN60950 |
Substation | IEC61850, IEEE1613 |
Accessories | Power Cord, 942 000-001 |
Scope of delivery | Device, General safety instructions |